Design Load Each 2.0KN,2.7KN when used in pairs.
L-33D/8 (Steel Thickness 8mm):Design Load Each 4.4KN,Used
in Paris only. |

Design Load Each 2.7KN,Used in Pairs only.
|

Design Load Each 2.0KN,4.9KN when used in pairs.
|

Design Load Each 2.1KN,4.0KN when used in pairs. |

Design Load Each 2.7KN,Used in Pairs only. |

Design Load Each 2.7KN,5.3KN when used in
pairs. |
 |
| Part No. |
Flange width(mm) |
Design Load(KN) |
| L-33JA |
60-114 |
5.3 |
| L-33JB |
95-146 |
3.6 |
| L-33JC |
143-194 |
2.5 |
| L-33KA |
60-114 |
5.3 |
| L-33KB |
95-146 |
5.3 |
| L-33KC |
143-194 |
5.3 |
|
 |
NOTE:
Safety factor is 5 for all beam clamps.
Either flange thickness and design load must be consideered when
used.
Above beam clamps must be used for less than 19mm of flange
thickess unless special specfied.Other flange thickness variations
are available,contact HengTeng Engineering for size. |